Continuous Glucose Monitor (CGM) Supply Allowance Calculator

  Loading

Glucose Monitors

Coverage

Documentation

Different Types of CGMS (Not all Inclusive)

Adjunctive or
Non-adjunctive
Stand-alone Integrated into Insulin Infusion Pump
(CGM Component is bolded)
Non-adjunctive CGMs
  • Dexcom G6
  • Dexcom G7 (with standalone receiver)
  • Abbott Freestyle Libre
  • Abbott Freestyle Libre 2
  • Abbott Freestyle Libre 3 (when used with a monitor)
  • Tandem t:slim X2 insulin pump + Abbott Freestyle Libre or Abbott Freestyle Libre 2
  • Tandem t:slim X2 insulin pump + Dexcom G6
Adjunctive CGMs NOT COVERED BY MEDICARE
  • Minimed Guardian Connect
(Any CGM that does not use a monitor(reader) is not covered by Medicare because without the monitor, it is not classified as DME)
  • Medtronic Minimed 630G + Minimed Guardian 3 CGM Sensor
  • Medtronic Minimed 670G + Minimed Guardian 3 CGM Sensor
  • Medtronic Minimed 770G + Minimed Guardian 3 CGM Sensor

Reviews/Audits

  • Medical Review - View notifications/findings of pre/post claim reviews completed by Noridian Medical Review

Continuous Glucose Monitors (CGM) procedure code update:

  • New HCPCS Codes (Effective for DOS on or after 01/01/2023)
    • A4239 - Supply allowance for non-adjunctive, non-implanted continuous glucose monitor (CGM), includes all supplies and accessories, 1month supply = 1 unit of service
    • E2103 - Non-adjunctive, non-implanted continuous glucose monitor or receiver
  • Deleted Codes (Effective for DOS prior to 01/01/2023)
    • K0553 - Supply allowance for therapeutic CGM device
    • K0554 - CGM receiver/monitor

Tips

Continuous Glucose Monitor (CGM) Supply Allowance Billing Monthly Supply Allowance

The supply allowance (A4239 or A4238) is billed as one unit of service per 30 days or three units of service per 90 days.

  • A4239 - Supply allowance for non-adjunctive, non-implanted continuous glucose monitor (CGM), includes all supplies and accessories
    • 1 month supply = 1 unit of service
    • 2 month supply = 2 units of service
    • 3 month supply = 3 units of service
  • A4238 - Supply allowance for adjunctive, non-implanted continuous glucose monitor (GGM), includes all supplies and accessories
    • 1 month supply = 1 unit of service
    • 2 month supply = 2 units of service
    • 3 month supply = 3 units of service

Because CGM supplies sometimes come as a 14-day supply kit, below is an example of billing the monthly supply allowance for a 1 month supply.

Example:

First Month - Provide three kits of supplies during month: 3 x 14-day supply = 42 day supply - Bill one supply allowance fee.

  • Will have 12 days of supplies left over for next month.

Second Month - Provide two kits of supplies during month: 2 x 14-day supply = 28 day supply - Bill one supply allowance fee.

  • Will have 10 days of supplies left over for next month.

Third month - Provide two kits of supplies during month: 2 x 14-day supply = 28 day supply - Bill one supply allowance fee.

  • Will have 8 days of supplies left over for next month.

Fourth month - Provide two kits of supplies during month: 2 x 14-day supply = 28 day supply - Bill one supply allowance fee.

  • Will have 6 days of supplies left over for next month.

Diabetic Supplies Used with Blood Glucose Monitor (BGM) and Continuous Glucose Monitor (CGM)

  • BGM supply HCPCS codes, along with CGM supply fee codes (A4239 or A4238) requires one of the below.
    • Beneficiary owned equipment be on file with Medicare Fee-for-service for HCPCS E0607, E2100, E2101, E2102, E2103, or E2104
      OR
    • A narrative on the claim line in item 19 of CMS-1500 Claim Form or the 2400/NTE segment of an electronic claim indicating beneficiary owned HCPCS E0607, E2100, E2101, E2102, E2103, or E2104 and its approximate purchase date
      • Example: Beneficiary owned E0607. Purchased 09/15/2022

If there is no glucose monitor in the Medicare claims history or the narrative is missing, the claim will deny as missing the equipment that requires the supply.

Resolving Denials

If a denial is received with Reason Code 16, Remark Code M124 that states: missing indication of whether the patient owns the equipment that requires the part or supply, the supplier must provide that information to Medicare to place on file. This can be accomplished by calling telephone reopening through the Supplier Contact Center and adding the information below on file.

  • Beneficiary owned item HCPCS; approximate purchased month and year
    • Example: Beneficiary owned E0607. Purchased 09/15/2022

Once the beneficiary-owned item is placed on file, subsequent supply claims do not require a narrative.

Continued Coverage for Continuous Glucose Monitor (CGM)

The treating practitioner must conduct, and sign follow up visits for Continuous Glucose Monitor (CGM) continued coverage. As noted in the Glucose Monitors Local Coverage Determination (LCD L33822), for continued CGM coverage, every six (6) months following the initial prescription of the CGM, the treating practitioner must conduct an in-person or Medicare-approved telehealth visit with the beneficiary to document adherence to their CGM regimen and diabetes treatment plan (emphasis added). For Medicare purposes, a pharmacist is not considered a statutorily recognized treating practitioner; therefore, a pharmacist entry in a beneficiary's medical record does not meet the continued coverage requirements in the Glucose Monitors LCD. Please see the Standard Documentation Requirements Article for a clear definition of who qualifies as a treating practitioner.

Diabetic Supplies and Accessories Used with CGM E2102 or E2103

Non-adjunctive CGM devices replace standard home BGMs (HCPCS codes E0607, E2100, E2101, and E2104) and related supplies (HCPCS codes A4233, A4234, A4235, A4236, A4244, A4245, A4246, A4247, A4250, A4253, A4255, A4256, A4257, A4258, A4259). Claims for a BGM and related supplies, billed in addition to a non-adjunctive CGM device (code E2103) and associated supply allowance (code A4239), will be denied.

Adjunctive CGM devices do not replace a standard home BGM. The supply allowance for an adjunctive CGM (A4238) encompasses all items necessary for the use of the device and includes but is not limited to, CGM sensors and transmitters. Code A4238 does not include a home BGM and related BGM testing supplies. These items may be billed separately, in addition to code A4238. Refer to the CODING GUIDELINES section in the LCD-related Policy Article for additional information.

Resource

Last Updated Aug 22 , 2024

Related Articles

paginationType noridian
Articles Source Posted
Glucose Monitors DME on Demands 09/11/2024
Continuous Glucose Monitors for Insulin Treated Beneficiaries 06/04/2024
Targeted Probe and Education (TPE) Pre-Payment Reviews 04/24/2024
2024 HCPCS Code Update - April Edition - Correct Coding 04/11/2024
HCPCS code A4238 and A4239 Claim Payment Alert - Resolved 02/28/24 Alert 02/28/2024
Continuous Glucose Monitor (CGM) Supply Allowance National DME MAC Education 02/21/2024
LCD and Policy Article Revisions Summary for December 14, 2023 12/14/2023
LCD and Policy Article Revisions Summary for November 9, 2023 11/09/2023
Continuous Glucose Monitors - No Prior Authorization Required for Medicare Fee-for-Service 11/02/2023
Treating Practitioner Must Conduct and Sign Any Follow Up Visits for Continuous Glucose Monitor (CGM) Coverage 09/18/2023
High Utilization for Home Blood Glucose Monitors (BGM) Supplies 06/23/2023
Glucose Monitors and Supplies L200 DME on Demands 05/23/2023
Glucose Monitors - Final LCD and Response to Comments (RTC) Article Published 03/02/2023
LCD and Policy Article Revisions Summary for March 2, 2023 03/02/2023
Continuous Glucose Monitors (CGM) Procedure Code Update 01/16/2023
Comment Period Closes November 19, 2022 for the Proposed Glucose Monitors LCD 11/10/2022
Open Meeting Announcement - Glucose Monitors Proposed Local Coverage Determination (LCD) 10/06/2022
Proposed Local Coverage Determination (LCD) Released for Comment - Glucose Monitors 10/06/2022
Continuous Glucose Monitor (CGM) Alert: What You Need to Know Following April 1 Code Changes 05/24/2022
LCD Revisions Summary for April 28, 2022 04/28/2022
LCD and Policy Article Revisions Summary for March 24, 2022 03/24/2022
PDAC Code Verification Reviews for CGM Devices - Coding and Billing 03/17/2022
Continuous Glucose Monitors - Correct Coding and Billing - Revised 03/17/2022